- removed a few remaing places where output wasn't being passed
through echo_i or cat_i
- added a "digcomp" function to conf.sh.in to send digcomp.pl output
through cat_i and return the correct exit value
- set SYSTESTDIR when calling echo_i from nsX directories, so that
the test name will always be printed correctly
- fixed a test name typo in conf.sh.in
As parallel.mk and runsequential.sh both pipe system test output through
"tee" (for the purpose of creating test.output), run.sh invoked from
these two files detects it is not writing to a terminal, which prevents
colored output from being generated. Allow forcing colored output using
a new command line argument for runall.sh, "-c", which sets an
environment variable (SYSTEMTEST_FORCE_COLOR) causing conf.sh to
unconditionally enable colored output.
The same environment variable can also be used directly to force colored
output when using "make test" instead of runall.sh.
It was TESTNAME, but this is an obvious name and was used in one of
the system tests, something that interfered with the content of
progress messages. It is now SYSTESTDIR.
Escape the line ends in a multi-line variable assignment. Under some
circumstances, substituting the variable caused syntax errors when
used as the list of values in a shell script "for" statement.
Miscellaneous tidying up of run management. The most significant
change is that "runall.sh" now runs _all_ the tests, even the
ones that can run in parallel. runsequential.sh is the script
to run tests that have not been converted to parallel running.
Currently these tests are allow_query, rpzrecurse and serve-stale
1. Function to copy files and set port numbers renamed from copy_config
to copy_setports, as this is used to change the ports in Perl and Python
test scripts as well.
2. Changes to rpzrecurse/tests.sh to handle two calls to getopts (one to
parse port numbers, the other to parse rpzrecurse-specific options). Also
fixed various commands to use correct ports.
3. Updates to "clean.sh" scripts to ensure that all files created in the
test are removed.
Via an intermediate make file, tests that have been modified to be able
to run in parallel are assigned unique query and control port numbers
(other than 5300 and 9953 respectively). Tests that have not yet been
modified all use ports 5300 and 9953, so must be run sequentially.
CNAME between to served zones when recursion was
desired and available (RD=1, RA=1). Don't return
the CNAME target otherwise to prevent accidental
cache poisoning. [RT #47078]
4757. [func] New "dnssec-cds" command creates a new parent DS
RRset based on CDS or CDNSKEY RRsets found in
a child zone, and generates either a dsset file
or stream of nsupdate commands to update the
parent. Thanks to Tony Finch. [RT #46090]
4749. [func] The ISC DLV service has been shut down, and all
DLV records have been removed from dlv.isc.org.
- Removed references to ISC DLV in documentation
- Removed DLV key from bind.keys
- No longer use ISC DLV by default in delv
[RT #46155]
4708. [cleanup] Legacy Windows builds (i.e. for XP and earlier)
are no longer supported. [RT #45186]
4707. [func] The lightweight resolver daemon and library (lwresd
and liblwres) have been removed. [RT #45186]
4706. [func] Code implementing name server query processing has
been moved from bin/named to a new library "libns".
Functions remaining in bin/named are now prefixed
with "named_" rather than "ns_". This will make it
easier to write unit tests for name server code, or
link name server functionality into new tools.
[RT #45186]
allows named to provide stale cached answers when
the authoritative server is under attack.
See max-stale-ttl, stale-answer-enable,
stale-answer-ttl. [RT #44790]
4637. [func] "nsec3hash -r" option ("rdata order") takes arguments
in the same order as they appear in NSEC3 or
NSEC3PARAM records, so that NSEC3 parameters can
be cut and pasted from an existing record. Thanks
to Tony Finch for the contribution. [RT #45183]
4549. [func] Added support for the EDNS TCP Keepalive option
(RFC 7828). [RT #42126]
4548. [func] Added support for the EDNS Padding option (RFC 7830).
[RT #42094]