geom_gettree probably never fails, and if it does there isn't much of
a fallback other than aborting partitioning. However, a few places
were checking the return value and not doing anything with it
triggering a unused-but-set-variable warning. Checking the errors
resolves the warning.
While here, check for errors in other places that weren't checking for
them at all, remove a spurious double call (the second call overwrote
the mesh structure leaking all the pointers from the first), and close
a few resource leaks on error paths.
Reviewed by: imp, emaste
Differential Revision: https://reviews.freebsd.org/D40779
The old one triggered a false positive -Warray-bounds from GCC (the
compiler assumed len was always 0), but it was also fragile with
manually computed lengths paired with strcat vs using a string
builder.
Differential Revision: https://reviews.freebsd.org/D40658
The SPDX folks have obsoleted the BSD-2-Clause-FreeBSD identifier. Catch
up to that fact and revert to their recommended match of BSD-2-Clause.
Discussed with: pfg
MFC After: 3 days
Sponsored by: Netflix
If the disk parameter "DEFAULT" is set in place of an actual device name,
or no disk is specified for the PARTITIONS parameter, the installer will
follow the logic used in the automatic-partitioning mode, in which it
will either provide a selection dialog for one of several disks if
several are present or automatically select it if there is only one. This
simplifies the creation of fully-automatic installation media for
hardware or VMs with varying disk names.
Suggested by: Egoitz Aurrekoetxea <egoitz@sarenet.es>
MFC after: 3 weeks
Relnotes: yes
Mainly focus on files that use BSD 2-Clause license, however the tool I
was using misidentified many licenses so this was mostly a manual - error
prone - task.
The Software Package Data Exchange (SPDX) group provides a specification
to make it easier for automated tools to detect and summarize well known
opensource licenses. We are gradually adopting the specification, noting
that the tags are considered only advisory and do not, in any way,
superceed or replace the license texts.
No functional change intended.
type. GEOM provider names can't duplicate (or shouldn't -- devfs will either
break or only use the first one if they do) so using the first provider
by that name is a sufficient check. This also lets the scripted partitioner
install onto gmirror and geli and such things.
will come soon. This lets the install process have a line like:
bsdinstall scriptedpart 'ada0 GPT {1.5G freebsd-ufs /, 10G freebsd-swap,
auto freebsd-ufs /usr}'
to set up a system with a 1.5GB /, some swap space, and a /usr using the
rest of ada0.
MFC after: 1 month