mirror of
https://github.com/opnsense/src.git
synced 2026-02-15 16:48:36 -05:00
Currently netfront is setting the flags of inbound packets with the checksum not present (offloaded) to (CSUM_IP_CHECKED | CSUM_IP_VALID | CSUM_DATA_VALID | CSUM_PSEUDO_HDR). According to the mbuf(9) man page this is not the correct combination of flags, it should instead be (CSUM_DATA_VALID | CSUM_PSEUDO_HDR). Reviewed by: Wei Liu <wei.liu2@citrix.com> MFC after: 2 weeks Sponsored by: Citrix Systems R&D Differential revision: https://reviews.freebsd.org/D9831 |
||
|---|---|---|
| .. | ||
| netfront.c | ||